Read and write series number:
Symbol
Byte
Definition
Note
CMD
1
0x6A Regulate other function
DAT1
1
0x10(write) 0x11(read) series number
DAT2
1
0~255Series number high
DAT3
1
0~255Series number low
DAT4
1
0
For example: high for 0x12, low for 0x34, then series number is 1234
Read and write communication address (not IP address):
Symbol
Byte
Definition
Note
CMD
1
0x6A Regulate other function
DAT1
1
0x20(write) 0x21(read) Local address
DAT2
1
0~99(Local address) 0 means broadcast
address
DAT3
1
0(no use)
DAT4
1
0(no use)
Local address is default for 0
LOGO Display Parameters Setting:
Symbol
Byte
Definition
Note
CMD
1
0x68
DAT1
1
0xf3
DAT2
1
1/0 Open/Close LOGO display
DAT3
1
1/0 Display/Cancel display customer
LOGO
DAT4
1
1-10 boot LOGO display time (second)